Regulating and Accuracy

How to Regulate a Seiko NH35 or 7S26

How to regulate a Seiko NH35 or 7S26 at home: realistic accuracy, timegrapher settings, finding the regulator under the rotor, and adjusting in small steps.

On this page
  1. What to expect from these movements
  2. NH35 vs 7S26: what differs when regulating
  3. Check first: is regulation the right fix?
  4. Tools
  5. Finding the regulator and stud levers
  6. Step by step
  7. Adjusting beat error on these calibers
  8. Common problems

What to expect from these movements

The Seiko NH35 and 7S26 are two of the most common automatic movements in the world. The 7S26 powered the Seiko 5 and the original SKX divers for years, and the NH35 (sold to other brands by Seiko’s movement division, and closely related to Seiko’s own 4R35) is used in Seiko watches and many microbrands.

Both run at 21,600 beats per hour, and both are robust, simple to work on and inexpensive. That makes them good movements to learn regulation on. They are not built to tight accuracy tolerances, though. The NH35’s daily-rate specification is commonly quoted as about −20 to +40 seconds per day. Many examples do much better than that, and with careful regulation a healthy one can often be brought to within a few seconds a day on the wrist, but a watch at +25 is technically within spec.

If you aren’t sure what counts as reasonable, see how many seconds per day is normal for a mechanical watch.

NH35 vs 7S26: what differs when regulating

The regulating parts on the balance are similar on both, so the method is largely the same. The practical differences are:

  • Hacking. The NH35 stops its seconds hand when the crown is pulled out to set the time; the 7S26 doesn’t. That makes the NH35 easier to set precisely when you are checking accuracy against reference time.
  • Hand-winding. The NH35 can be wound with the crown; the 7S26 can only be wound by the rotor. To get a 7S26 to full wind before testing, wear it for a while or swing it gently by hand. Readings on a partially wound watch can be misleading.
  • Jewels. The 7S26 has 21 jewels and the NH35 has 24, but that doesn’t change how you regulate them.

Check first: is regulation the right fix?

Before you open the case:

  • Is it magnetized? If the watch suddenly started gaining a lot, check how to tell if a watch is magnetized. Magnetism is very common and is fixed by demagnetizing, not regulating.
  • Is it fully wound? Especially with a 7S26, which can’t be hand-wound.
  • Is the amplitude reasonable? Seiko’s workhorse movements often show lower amplitude than Swiss movements and still keep decent time, but a very low reading in every position usually means a service is due. The article on what is good amplitude for a mechanical watch gives ranges.
  • Is the rate stable? If it jumps around from day to day, regulation won’t help.

Tools

  • A case opener that fits. Most Seiko 5 and SKX-style cases have screw-down backs; see how to open a screw back watch case.
  • A timegrapher or timing app, set to 21,600 bph and a lift angle of 53 degrees, which is the figure commonly given for this movement family.
  • A fine non-magnetic tool: brass tweezers, a small plastic-tipped tool, or a finely sharpened piece of pegwood. A very small screwdriver also works if you are careful. See watchmaker screwdriver sizes for blade sizes.
  • A loupe and good light.
  • A movement holder or soft cloth to support the case, plus a dust cover.

Finding the regulator and stud levers

Under the balance cock (the bridge that holds the balance wheel) there are two adjustable parts on these calibers:

  • The regulator arm. This carries the regulator pins that sit either side of the hairspring. Moving it changes the rate. It usually has a tail that you can push toward “+” (faster) or “−” (slower). Not every example has clear markings; if yours doesn’t, make a very small test move and check the timegrapher to see which way the rate went.
  • The stud holder. This holds the outer end of the hairspring. Moving it changes beat error, and also shifts the rate a little.

The two can look similar at first glance. Take time to identify them, ideally comparing your movement to a clear photo of the same caliber, before touching anything.

Step by step

Baseline readings

Wind fully (or wear the watch for several hours if it is a 7S26). On a timegrapher, record rate, amplitude and beat error in at least dial up, dial down and crown down, plus any other positions you can. The guide on how to read a timegrapher explains each figure.

Work out the average of the positions that best represent how you wear the watch. That average is what you’re trying to correct.

Opening the case

Clean the case first so grit doesn’t fall into the movement. Hold the watch securely and open the case back with the right tool. Set the case back aside, gasket side up, somewhere clean.

Getting past the rotor

The rotor partly covers the balance on these movements. On many examples you can gently turn the rotor by hand so it sits away from the balance cock, giving enough room to work. Hold it there lightly with a finger or a soft tool, or let it rest where it settles.

Removing the rotor is possible but adds steps and a chance of damage or losing a part. For a simple regulation job, turning it aside is usually enough.

Moving the regulator

Under magnification, place the tip of your tool against the regulator tail and move it a very small amount: toward “+” if the watch is losing, toward “−” if it’s gaining.

Small really means small. On these movements a movement of the tail that is hard to see can change the rate by several seconds a day. Never let the tool touch the hairspring.

Re-test and close

Put the watch back on the timegrapher, wait a minute, and check the rate in the same positions as before. Repeat small adjustments until the average is where you want it. A slight gain of a few seconds a day is a common target.

Then check that the case back gasket is clean and seated, and close the case evenly. Opening the case can affect water resistance; if you plan to swim with the watch, a pressure test is the only way to be sure it is still sealed.

Finally, wear the watch for several days and compare with reference time. The method in how to check watch accuracy at home works well for the final check.

Adjusting beat error on these calibers

Because the stud holder is adjustable, beat error can be corrected without removing the balance. If beat error is high and the watch also struggles to start or stops early, it may be worth correcting:

  1. Note the current beat error.
  2. Move the stud holder a tiny amount and re-read.
  3. If the number went up, move back the other way.
  4. Once beat error is low, check the rate again and re-regulate if needed.

Correct beat error before regulating, not after, because the stud adjustment shifts the rate. The article on what is beat error on a watch explains when it is worth bothering.

Common problems

  • The rate keeps changing after adjustment. Let the watch settle and re-check fully wound. If it is still unstable, the movement may need cleaning and oiling.
  • The regulator is already near the end of its travel. That suggests something other than regulation is wrong, such as magnetism, old lubrication or a hairspring issue.
  • The watch stopped after you worked on it. Check that nothing is touching the balance, including the rotor and your tool. If the hairspring has been bent or caught, stop and take it to a watchmaker.
  • Dust or a hair on the balance. Erratic timing after opening the case can come from debris. Keep the movement covered between steps.

If you would rather practice on a movement before working on a watch you care about, an inexpensive loose NH35 is a common choice; the article on the best movement to practice watch repair suggests others. For the general principles behind all of this, see how to regulate a mechanical watch.

The complete guide to regulating and accuracy

How to Regulate a Mechanical Watch
Read the guide

Keep exploring

Guides from other topics

All topics →