Regulating and Accuracy

How to Regulate an ETA 2824 or Sellita SW200

How to regulate an ETA 2824-2 or Sellita SW200: grade tolerances, timegrapher settings, using the Etachron-style index and stud carrier, and common pitfalls.

On this page
  1. Why these two are regulated the same way
  2. Grades and what accuracy to expect
  3. Timegrapher settings for these calibers
  4. The Etachron-style regulator
  5. Step by step
  6. Pitfalls
  7. When to stop and send it out

Why these two are regulated the same way

The ETA 2824-2 has been one of the most widely used Swiss automatic movements for decades. The Sellita SW200-1 is closely based on it and is widely described as dimensionally interchangeable, so the two share the same basic layout, including the regulating parts on the balance cock. Both run at 28,800 beats per hour.

That means the process below applies to both. There are small differences between versions and grades, so look at your own movement carefully before adjusting.

Grades and what accuracy to expect

ETA has produced the 2824-2 in several grades. They share the same basic architecture but differ in regulation, components and finishing. The commonly quoted figures are:

Grade Positions adjusted Average daily rate Maximum variation
Standard 2 about ±12 s/d about ±30 s/d
Elaboré 3 about ±7 s/d about ±20 s/d
Top 5 about ±4 s/d about ±15 s/d
Chronometer COSC certified −4/+6 s/d per COSC limits

Sellita uses its own grade names for the SW200-1, broadly along similar lines. You often won’t know which grade is in a watch without opening it, and sometimes not even then.

These figures tell you what “normal” looks like. A standard-grade watch at +8 seconds a day isn’t faulty. For more context, see how many seconds per day is normal for a mechanical watch.

Timegrapher settings for these calibers

  • Beat rate: 28,800 bph.
  • Lift angle: 50 degrees, which is the figure listed for both the ETA 2824-2 and the SW200.

Many timegraphers default to a lift angle of 52 degrees. That doesn’t change the rate reading, but it makes the amplitude figure less accurate. Setting it to 50 gives a more trustworthy amplitude. The guide on how to read a timegrapher explains the readings.

The Etachron-style regulator

The standard-grade 2824-2 uses ETA’s Etachron regulating system, and the SW200 uses a similar design. On the balance cock you’ll typically find:

  • The index (regulator arm). It carries the regulator pins that hold the outer coil of the hairspring. Moving the index toward “+” makes the watch run faster; toward “−”, slower.
  • The stud carrier. A separate part that holds the hairspring stud. Turning it moves the balance’s resting point, which corrects beat error.

On many examples, both parts can be moved with a fine screwdriver or a pointed tool against a small slot or tab. Some higher grades have a fine-adjustment mechanism for the index, such as an eccentric screw, which allows more precise moves. Identify which part is which on your movement before touching either.

Step by step

Baseline in several positions

Wind the watch fully by hand; both movements can be hand-wound through the crown. On the timegrapher, record rate, amplitude and beat error in at least dial up, dial down, crown down and crown up, and ideally crown left and right as well.

Calculate the average rate and note the spread between positions. If the spread is very large, regulation alone won’t fix it; see what is positional variance in a watch.

Also check that amplitude is healthy. On a well-serviced 2824 or SW200, a fully wound dial-up reading in the high 200s is common, with lower readings in vertical positions. If amplitude is low everywhere, a service is likely due before regulating makes sense. See what is good amplitude for a mechanical watch.

Open the case and access the balance

Many watches with these movements have screw-down case backs. Use a proper case opener and support the case well; the guide on how to open a screw back watch case covers technique.

The rotor sits over part of the movement. On many watches you can rotate it gently so it’s clear of the balance cock. Removing the rotor is possible but usually unnecessary for regulation.

Adjust rate with the index arm

Under magnification, place a fine tool against the index and move it a very small amount: toward “+” if losing, toward “−” if gaining. If your movement has a fine-adjustment screw, turn it a small fraction of a turn instead.

Let the balance settle for a minute, then re-read in the same positions. Continue in small steps. The aim is usually a small average gain, a few seconds a day, rather than a perfect zero in one position.

Adjust beat error with the stud carrier

If beat error is high, correct it before finishing the rate. Move the stud carrier a tiny amount, re-read, and reverse if the number got worse. Once beat error is low, re-check the rate, because moving the stud carrier usually shifts it slightly.

The article on what is beat error on a watch explains when correcting it is worthwhile.

Re-test, close and verify

When you’re happy, check the case back gasket for damage and dirt, then close the case. If the watch is meant to be water resistant and you intend to rely on it, a pressure test is the way to confirm it is still sealed.

Then wear the watch for several days and track its real-world rate against reference time. The method in how to check watch accuracy at home works well. Bench readings and on-wrist results often differ a little.

Pitfalls

  • Confusing the index and the stud carrier. Moving the wrong one changes beat error instead of rate, or the other way round.
  • Touching the hairspring. Even a light brush can deform it.
  • Magnetized tools. Use non-magnetic tools or demagnetize them first. If the watch’s rate suddenly jumps afterward, check how to tell if a watch is magnetized.
  • Over-adjusting. Large movements of the index make the rate jump and are easy to overshoot.
  • Trusting one position. A watch that reads 0 dial up may still gain or lose on the wrist.
  • Working with a partly wound watch. Low wind lowers amplitude and can change the rate and beat error readings.

When to stop and send it out

Stop and consider a watchmaker if:

  • The index is already near the end of its travel.
  • Amplitude is low in every position.
  • The rate is unstable between readings.
  • The hairspring looks uneven, tangled or touches anything.
  • The watch is valuable, under warranty, or water resistance matters to you.

A watchmaker will usually regulate the watch as part of a service. For a broader overview of the technique that applies to other movements too, see how to regulate a mechanical watch.

The complete guide to regulating and accuracy

How to Regulate a Mechanical Watch